Kundservice Snabb leverans For företag och privat
Betyg
0 0

Kommentering är inte påslagen på denna kursen.

3. BLS 200 SERIES FILTERS WITH BAYONET CONNECTION BLS SRL via dei Giovi, 41 20032 Cormano (MI) - Italy t/f +39 0239310212 / 0266200473 info@blsgroup.it - www.blsgroup.com TDS-BLS200-FILTER_BLOCK-EN P 3/3 Dust Half masks BLS 4000 S - BLS 4000 R Full face masks BLS 5700 - BLS 5600 Gases&vapours Combined BLS declines any responsibility, direct or indirect, from any misuse of both devices and instructions. User is responsible for the deter - mination of product compliance with the intended use. MODEL CODE PROTECTION WEIGHT (g) ± 3 Q.TY/BOX Q.TY/CARTON CARTON WEIGHT (Kg) ± 0,1 BLS 202 8011118 P3 R 67 8 64 5,9 BLS 211 8011109 A2 89 8 64 7,3 BLS 212 8011205 AX 111 8 64 5,7 BLS 213 8011110 ABE1 100 8 64 7,8 BLS 214 8011111 ABEK1 106 8 64 8,3 BLS 221 8011112 A2P3 R 135 8 64 10,4 BLS 222 8011113 ABEK1P3 R 149 8 64 11,3 BLS 225 8011206 AXP3 NR 157 4 32 6,6 BLS 226 8011145 ABE1P3 R 139 8 64 10,7 BLS 227 8117029 ABEK1HgP3 149 8 64 11,3 BLS 242 8011133 ABE2 125 8 64 10,0 BLS 243 8011114 ABEK2 139 8 64 10,5 BLS 244 8011134 K2 142 8 64 10,5 BLS 253 8011140 ABE2P3 R 175 4 32 6,8 BLS 254 8011141 ABEK2HgP3 R 180 4 32 7,4 CLASS • Determines the duration of the filter: • Class 1 = 1000 ppm, Class 2 = 5000 ppm COLOUR CODES A = Organic gases and vapours AX = Organic gases and vapours (Boiling point <65 ° C) B = Inorganic gases and vapours E = Acid gases and vapours K = Ammonia and derivatives Hg = Mercury vapour P = Dusts TYPES OF FILTERS COMPATIBLE DEVICES TRANSPORT IMPORTANT SELECTION GUIDE

1. BLS 200 SERIES FILTERS WITH BAYONET CONNECTION BLS SRL via dei Giovi, 41 20032 Cormano (MI) - Italy t/f +39 0239310212 / 0266200473 info@blsgroup.it - www.blsgroup.com TDS-BLS200-FILTER_BLOCK-EN P 1/3 Wide range of filters for dust, gases and combined protection, to be used with BLS 4000next series half- masks and BLS 5000 series full-face masks. They are highly efficient, easy to use and highly secure. This connection is highly intuitive allowing a quick and safe hold on the mask. It has a locking feedback allowing the user to know if the filter has been properly placed. Off-centre connection to shift the centre of gravity of the filter and improve weight distribution and field of vision. The quality of the activated carbons used by BLS for the filtration of gases and vapours, meets high standards of safety ensuring excellent filtration performances. They are produced without toxic additives such as Hexavalent Chromium (Cr VI). Filtering efficiency is 99,99%. The integrity of the filtering material is ensured by a protective mesh. ACTIVATED CARBONS DUST FILTER Specific tests show that ABEK and ABE special BLS carbons are capable to guarantee protection from formaldehyde. Even with class 1 filters it’s possible to achieve proper protection. At the end of the test the detected concentration of formaldehyde at the end of the filter is lower than half the Threshold Limit Value according to NIOSH TEB-APR-STP-0039A (Breakthrough Point). Made of non deformable ABS allows to have a absolute control over the compression of the activated carbon grains within, this way air corridors are completely avoided making the filter 100% safe. FILTER CANISTER TESTED ON FORMALDEHYDE BAYONET CONNECTION

2. BLS 200 SERIES FILTERS WITH BAYONET CONNECTION BLS SRL via dei Giovi, 41 20032 Cormano (MI) - Italy t/f +39 0239310212 / 0266200473 info@blsgroup.it - www.blsgroup.com TDS-BLS200-FILTER_BLOCK-EN FILTER’S CANISTER Acrylonitrile butadiene styrene (ABS) DUST FILTERING MATERIAL Pleated glass fibre GASES AND VAPOURS FILTERING MATERIAL Activated carbons grains SHELF-LIFE 5 years TEMPERATURE -10° / +50° C RELATIVE HUMIDITY 70% max MATERIALS STORAGE P 2/3 BLS filters are: • Certified according to European Regulation 2016/425 (Personal Protective Equipments) • Certified as PPE of III category, in presumption of conformity to harmonized standard EN 143:2000 + A1:2006 and EN 14387:2004 + A1:2008 • Certified and controlled according to Annex D by Italcert S.r.l. (Notified Body n°0426) • CE marked BLS management system is ISO 9001 certified CERTIFICATION MODEL PROTECTION TYPE TESTED on FORMALDEHYDE TESTED on FLUORIDRIC ACID NPF (half masks) NPF (full face masks) CONNECTION BLS 202 (2) P3 R Dust _ _ 48*TLV 1000*TLV Bayonet (b-lock) BLS 211 A2 Gases&vapours _ _ 50*TLV 2000*TLV Bayonet (b-lock) BLS 212 AX Gases&vapours _ _ 50*TLV 2000*TLV Bayonet (b-lock) BLS 213 ABE1 Gases&vapours _ _ 50*TLV 2000*TLV Bayonet (b-lock) BLS 214 ABEK1 Gases&vapours _ _ 50*TLV 2000*TLV Bayonet (b-lock) BLS 221 A2P3 R Combined _ _ 48*TLV 1000*TLV Bayonet (b-lock) BLS 222 ABEK1P3 R Combined _ 48*TLV 1000*TLV Bayonet (b-lock) BLS 225 (1) AXP3 NR Combined _ _ 48*TLV 1000*TLV Bayonet (b-lock) BLS 226 ABE1P3 R Combined _ _ 48*TLV 1000*TLV Bayonet (b-lock) BLS 227 ABEK1HgP3 Combined _ _ 48*TLV 1000*TLV Bayonet (b-lock) BLS 242 ABE2 Gases&vapours _ 50*TLV 2000*TLV Bayonet (b-lock) BLS 243 ABEK2 Gases&vapours _ 50*TLV 2000*TLV Bayonet (b-lock) BLS 244 K2 Gases&vapours _ _ 50*TLV 2000*TLV Bayonet (b-lock) BLS 253 (1) ABE2P3 R Combined _ _ 48*TLV 1000*TLV Bayonet (b-lock) BLS 254 (1) ABEK2HgP3 R Combined _ _ 48*TLV 1000*TLV Bayonet (b-lock) (TLV) Threshold Limit Value (NPF) Nominal Protection Factor (1) These filters cannot be used with half masks because their weight is greater than 300g (2) TThese filters have been tested by the Itene laboratory (University of Valencia), which has certified their 99% filtering efficiency against nanoparticles (diameter down to 0.04 microns) Test Report Itene 10.09.2022 TECHNICAL DATA

Säkerhet för alla

Håll dig säkert uppdaterad med de senaste nyheterna och kunskapen inom PPE och arbetsmiljö