Documentation
Slutförd
Ose_directory e-shot
3675 Visningar •Kontrollera linje II underhållsmanual
4566 Visningar •Chemsplash Pro WD40 Test
4176 Visningar •ergonomi 2006
4529 Visningar •Ose_directory Suspension sele
3972 Visningar •Köpguide annonsen Health and Safety International - Europas tidskrift för anställda skydd och personlig skyddsutrustning
4896 Visningar •Demonstration av kardborreband för montering / installation av gasdetektor i fallskyddssele
4712 Visningar •VISOR Installationssteg
4996 Visningar •Desinfektionsprodukter med effekt på Corona Virus 2019 Ncov
4144 Visningar •Hörselskydd 3M
3583 Visningar •Statistik för arbete under 2014
4228 Visningar •LOTO_GuideBook_Europe_English
4368 Visningar •Remote Area Lighting System
3122 Visningar •Isol8 - The Ultimate absorberande för spill
3120 Visningar •Work Magazine - November 2012
3471 Visningar •KEE_DOME_MINI
3414 Visningar •TDS Speedglas 9100
3633 Visningar •Pocket Book of Lean Visuals
3653 Visningar •Instruktionsfilmer Sign hållare
2916 Visningar •PREMARK installationsmanual
3777 Visningar •D-S CSR Handbook
19845 Visningar •Hitta handske storlek - Storleksguide för handskar
12839 Visningar •Quick guide 3M PELTOR WS ProTac XPI_advanced (1)
8589 Visningar •3M jupiter manuell
8371 Visningar •83735-00000A Safety Data Sheet
8278 Visningar •D S 70:e oss broschyr
7489 Visningar •9100 Manuell
7319 Visningar •Förklaring av den nya EN ISO 374 standard kemikalier
6577 Visningar •LA600 UI A3 26 LANGUAGES 22 08 2019 598
6482 Visningar •EN 388 nya etiketter förklaring
6428 Visningar •Fallskydd flyer
6373 Visningar •Hur man kalibrerar en 3M Jupiter luftflödesenhet
6004 Visningar •3M TR 300 PAPR utbildning video
5689 Visningar •TR-300 Bruksanvisning
5297 Visningar •GuardianChemicalReport
5215 Visningar •Urvalsguide respirator
5005 Visningar •VISOR Installationssteg
4996 Visningar •VARMEX 2000 Fördelar
4995 Visningar •Köpguide annonsen Health and Safety International - Europas tidskrift för anställda skydd och personlig skyddsutrustning
4896 Visningar •Demonstration av kardborreband för montering / installation av gasdetektor i fallskyddssele
4712 Visningar •PAF-0060-CleanSpace-EX-Intrinsically-Safe-Approvals-Explained
Kommentering är inte påslagen på denna kursen.
2. IECE x APPROVALS (INTERNATIONAL INTRINSICALLY SAFE REQUIREMENTS) Ex ia I Ma Ex – Explosion Proof Certification ia – Ignition Protection Level: Intrinsic Safety, Very High level of protection. Suitable for use in Zones 0, 1, & 2. I – Gas Subdivision Group: Represented by Methane Gas. Ma – Equipment Protection Level: Very High Level of Protection against methane & coal dust in underground mines. Ex ib IIB T4 Gb Ex – Explosion Proof Certification ib – Ignition Protection Level: Intrinsic Safety, High level of protection. Suitable for use in Zones 1 & 2. IIB – Gas Subdivision Group: Represented by Ethylene. Includes less ignitable groups IIA (Propane) and I (Methane). T4 – Temperature Class: Max Surface Temperature of 135 ̊C. Gb – Equipment Protection Level: High, Suitable for use in Zones 1 & 2 in aboveground explosive environments. Reference Standard Description IECEx Standards IEC 60079-0:2017 General Requirements IECEx Standards IEC 60079-11:2011 Equipment Protection by Intrinsic Safety (i) IECEx Quality Assurance IEC 80079-34:2018 Application of Quality Management Systems for Ex Product Manufacture Cleanspace Technology Pty Ltd ABN 24 146 453 554 T: +61 2 8436 4000 U5, 39 Herbert Street St. Leonards NSW 2065 Australia sales@cleanspacetechnology.com www.cleanspacetechnology.com NE002530 SUMMARY: Suitable for use in underground mining applications Zones 0, 1 & 2 with presence of methane gas & coal dust that requires a very high level of equipment protection and very high level of ignition protection. SUMMARY: Suitable for use in above ground applications Zones 1 & 2 with gases up to Ethylene that require a high level of equipment protection and a high level of ignition protection against gas, vapor and mist. Not suitable for use in Zone 0. This information is a guide only and is not intended to be comprehensive. We recommend a safety manager or qualified technical engineer is consulted. ATEX/IECEx Definitions Equipment Group (ATEX Only) I Underground mining operations Equipment Protection Level Ma Very High against Methane & Coal Dust II Operations other than underground mines Mb High against Methane & Coal Dust Ga Very High against Gas, Mist & Vapor Equipment Category M1 Two Faults Gb High against Gas, Mist & Vapor M2 Severe Normal Operation Gc Normal against Gas, Mist & Vapor 1 Two Faults 2 One Fault Area Classification Category 1 Zone 0 – A place in which an explosive atmosphere consisting of a mixture with air of dangerous substances in the form of gas, vapor or mist is present continuously or for long periods or frequently. 3 Normal Operation Explosive Atmosphere G Gas, Vapor, Mist D Dust Explosion Protection (Ex) ia Intrinsic Safety - Very High Ignition Protection Category 2 Zone 1 – A place in which an explosive atmosphere consisting of a mixture with air of dangerous substances in the form of gas, vapor or mist is likely to occur in normal operation occasionally. ib Intrinsic Safety - High Ignition Protection Gas Subgroup I Methane-Least easily ignited IIA Propane-Less easily ignited IIB Ethylene-More easily ignited Category 3 Zone 2 – A place in which an explosive atmosphere consisting of a mixture with air of dangerous substances in the form of gas, vapor or mist is not likely to occur in normal operation but, if it does occur, will persist for a short period only. IIC Hydrogen/Acetylene-Most easily ignited Temperature Class (Max Surface Temp) T3 200 ̊C T4 135 ̊C T5 100 ̊C
1. CLEANSPACE EX PAPR INTRINSIC APPROVALS PAF-0060 ATEX APPROVALS (REQUIRED FOR EU COUNTRIES) I M1 Ex ia I Ma I – Equipment Group: Suitable for use in underground mines. M1 – Equipment Category: Mines involving methane gas. Ex ia – Ignition Protection Level: Intrinsic Safety, Very High level of protection. Suitable for use in Zones 0, 1, & 2. I – Gas Subdivision Group: Represented by Methane Gas. Ma – Equipment Protection Level: Very High Level of Protection against methane & coal dust in underground mines. II 2 G Ex ib IIB T4 Gb II – Equipment Group: Suitable for use in aboveground explosive atmospheres. 2G – Equipment Category: Aboveground explosive environments involving Gas, Vapor, Mist. Ex ib – Ignition Protection Level: Intrinsic Safety, High level of protection. Suitable for use in Zones 1 & 2. IIB – Gas Subdivision Group: Represented by Ethylene. Includes less ignitable groups IIA (Propane) and I (Methane). T4 – Temperature Class: Max Surface Temperature of 135 ̊C. Gb – Equipment Protection Level: High, Suitable for use in Zones 1 & 2 in aboveground explosive environments. Reference Standard Description ATEX / EN EX Standards EN 60079-0:2018 General Requirements ATEX / EN EX Standards EN 60079-11:2012 Equipment Protection by Intrinsic Safety (i) ATEX Quality Assurance Annex IV, Directive 2014/34/EU Conformity to Type Based on Quality Assurance of the Production Process ATEX/IECEx Definitions Equipment Group (ATEX Only) I Underground mining operations Equipment Protection Level Ma Very High against Methane & Coal Dust II Operations other than underground mines Mb High against Methane & Coal Dust Ga Very High against Gas, Mist & Vapor Equipment Category M1 Two Faults Gb High against Gas, Mist & Vapor M2 Severe Normal Operation Gc Normal against Gas, Mist & Vapor 1 Two Faults 2 One Fault Area Classification Category 1 Zone 0 – A place in which an explosive atmosphere consisting of a mixture with air of dangerous substances in the form of gas, vapor or mist is present continuously or for long periods or frequently. 3 Normal Operation Explosive Atmosphere G Gas, Vapor, Mist D Dust Explosion Protection (Ex) ia Intrinsic Safety - Very High Ignition Protection Category 2 Zone 1 – A place in which an explosive atmosphere consisting of a mixture with air of dangerous substances in the form of gas, vapor or mist is likely to occur in normal operation occasionally. ib Intrinsic Safety - High Ignition Protection Gas Subgroup I Methane-Least easily ignited IIA Propane-Less easily ignited IIB Ethylene-More easily ignited Category 3 Zone 2 – A place in which an explosive atmosphere consisting of a mixture with air of dangerous substances in the form of gas, vapor or mist is not likely to occur in normal operation but, if it does occur, will persist for a short period only. IIC Hydrogen/Acetylene-Most easily ignited Temperature Class (Max Surface Temp) T3 200 ̊C T4 135 ̊C T5 100 ̊C SUMMARY: Suitable for use in underground mining applications Zones 0, 1 & 2 with presence of methane gas & coal dust that requires a very high level of equipment protection and very high level of ignition protection. SUMMARY: Suitable for use in aboveground applications Zones 1 & 2 with gases up to Ethylene that require a high level of equipment protection and a high level of ignition protection against gas, vapor and mist. Not suitable for use in Zone 0. WWW.CLEANSPACETECHNOLOGY.COM sales@cleanspacetechnology.com
Dela detta innehåll
Dela länk
Dela på sociala medier
Dela via e-post
Snälla logga in att dela detta Dokument via e-post.