Documentation
Slutförd
Ose_directory e-shot
3460 Visningar •Kontrollera linje II underhållsmanual
4261 Visningar •Chemsplash Pro WD40 Test
3959 Visningar •ergonomi 2006
4223 Visningar •Ose_directory Suspension sele
3722 Visningar •Köpguide annonsen Health and Safety International - Europas tidskrift för anställda skydd och personlig skyddsutrustning
4511 Visningar •Demonstration av kardborreband för montering / installation av gasdetektor i fallskyddssele
4445 Visningar •VISOR Installationssteg
4750 Visningar •Desinfektionsprodukter med effekt på Corona Virus 2019 Ncov
3865 Visningar •Hörselskydd 3M
3357 Visningar •Statistik för arbete under 2014
3975 Visningar •LOTO_GuideBook_Europe_English
4108 Visningar •Remote Area Lighting System
2918 Visningar •Isol8 - The Ultimate absorberande för spill
2907 Visningar •Work Magazine - November 2012
3234 Visningar •KEE_DOME_MINI
3151 Visningar •TDS Speedglas 9100
3381 Visningar •Pocket Book of Lean Visuals
3370 Visningar •Instruktionsfilmer Sign hållare
2646 Visningar •PREMARK installationsmanual
3431 Visningar •D-S CSR Handbook
19412 Visningar •Hitta handske storlek - Storleksguide för handskar
12422 Visningar •83735-00000A Safety Data Sheet
8028 Visningar •3M jupiter manuell
7932 Visningar •Quick guide 3M PELTOR WS ProTac XPI_advanced (1)
7201 Visningar •9100 Manuell
6957 Visningar •D S 70:e oss broschyr
6880 Visningar •LA600 UI A3 26 LANGUAGES 22 08 2019 598
6221 Visningar •Förklaring av den nya EN ISO 374 standard kemikalier
6208 Visningar •EN 388 nya etiketter förklaring
6149 Visningar •Fallskydd flyer
6006 Visningar •Hur man kalibrerar en 3M Jupiter luftflödesenhet
5746 Visningar •3M TR 300 PAPR utbildning video
5245 Visningar •TR-300 Bruksanvisning
4911 Visningar •GuardianChemicalReport
4887 Visningar •VISOR Installationssteg
4750 Visningar •Urvalsguide respirator
4714 Visningar •VARMEX 2000 Fördelar
4692 Visningar •Köpguide annonsen Health and Safety International - Europas tidskrift för anställda skydd och personlig skyddsutrustning
4511 Visningar •Demonstration av kardborreband för montering / installation av gasdetektor i fallskyddssele
4445 Visningar •I-test-Data-Sheet-European-English
Kommentering är inte påslagen på denna kursen.
1. I-Test Automated Portable Gas Detector Test Station Quick Automated Compliance
3. I-Test Manager I-Test Manager is Crowcon’s software solution for the control of your data that has been collected through the I-Test. The software platform is intuitive and can be used by multiple users giving you the ability to run the correct reports for your department. With the I-Test Manager you can do the following: Simple to use When the Gas-Pro or T4 are inserted into I-Test, no button presses are required and I-Test starts testing automatically. A bump test takes less than 1 minute. The test carries out verification that the sensors are responding to a known value of gas, and filters are clear and good for use. It will also ensure the audible and visual alarms are working, giving the user full confidence that they are compliant for site use. Manage cylinders View data Field configuration Create reports Inlet configuration Exception reporting • Data reporting in graph form • Search by date • Full site record keeping • Ensure gas is tracked • Ensure gas is in date • Flexibility of concentrations • Site compliant • Tailored reporting • Print or save certificates • Change a fleet easily • Ensure unit is up to latest standards • No down time • Ensure everyone is following site rules • Report on missing units • Flexibility on reports • Flexibility of use • Ensure correct gas is being used
2. Flexible Mains powered, or battery back-up Allows you to use on site, or in field Entirely self-contained No extra computers or equipment required Ability to update Gas-Pro and T4 configurations Update the bump test interval or alarm levels of your fleet with ease and no fleet downtime Data management Archive gas level data from detectors long term Powerful support software Makes configuring I-Test to site requirements extremely easy Reliable I-Test recognises empty or expired cylinders Allows for planned refills and no unit downtime Testing starts automatically when detector is inserted Minimal user training required Ensures the audible and visual alarms are working Gives the user full confidence that the Gas-Pro is compliant to use Battery backup Testing continues even if power is out Records Everything is logged See everything that has been tested and whether it has passed/failed Exception reporting Precise reports flag up who has and hasn’t carried out their bump test or calibration Powerful reporting Need to see which detectors have gone in to alarm in the last month? I-Test Manager makes easy work of pulling report summaries together Ensuring your site is compliant I-Test is Crowcon’s fully automated solution for testing and verifying that your Gas-Pro and T4 are in a compliant state to carry out your daily work. Bump testing standards are getting tighter in all regions and the need for controlled bump and calibration records is a must. I-Test and the accompanying I-Test manager software makes this easy. It takes less than 1 minute to complete a bump test with I-Test I-Test Automated Bump Test Station
4. www.crowcon.com © 2022 Crowcon Detection Instruments Ltd. Copyright to some photographs held separately. Specification Size 110 x 250 x 320mm (4.3 x 9.8 x 12.6 ins) Weight 2kg (70.5oz) Input Supply 9-12V @ 3A I-Test backup battery 200 speedy bump tests with 15-second intervals between tests 5 hours in standby with no bump test Battery life approximately 500 cycles Charge time 7 hours RTC backup battery 3-year life USB interface One standard USB type A socket for USB Flash Memory stick One standard USB type B socket for connections to PC Inlets/Outlets Single gas inlet (requires demand flow regulator) Purge inlet (air) Exhaust Regulators Demand flow regulator required Storage capacity Internal 2GB MicroSD card Temperature specifications Operating temperature: -10 o C to +50 o C Storage temperature: -25 o C to +60 o C Charging temperature: 0 o C to +40 o C Humidity 0% and 95% relative humidity (non-condensing) at +40 o C Ingress protection IP20 Accessories Demand flow regulator Calibration gas Cylinder holder Crowcon reserves the right to change the design or specification of the product without notice. Disclaimer Every effort has been made to ensure the accuracy of this document at the time of printing. In accordance with the company’s policy of continued product improvement Crowcon Detection Instruments Limited reserves the right to make product changes without notice. The products are routinely subject to a programme of testing which may result in some changes in the characteristics quoted. Technical information contained in this document or otherwise provided by Crowcon are based upon records, tests, or experience that the company believes to be reliable, but the accuracy, completeness, and representative nature of such information is not guaranteed. Many factors beyond Crowcon Detection Instruments’ control and uniquely within user’s knowledge and control can affect the use and performance of a Crowcon product in a particular application. As the products may be used by the client in circumstances beyond the knowledge and control of Crowcon Detection Instruments Limited, we cannot determine the relevance of these to an individual customer’s application. It is the clients’ sole responsibility to carry out the necessary tests to evaluate the usefulness of the products and review all applicable regulations and standards to ensure their safety of operation in a particular application.
Dela detta innehåll
Dela länk
Dela på sociala medier
Dela via e-post
Snälla logga in att dela detta Dokument via e-post.