Documentation
Slutförd
Ose_directory e-shot
4140 Visningar •Kontrollera linje II underhållsmanual
5154 Visningar •Chemsplash Pro WD40 Test
4592 Visningar •ergonomi 2006
5130 Visningar •Ose_directory Suspension sele
4419 Visningar •Köpguide annonsen Health and Safety International - Europas tidskrift för anställda skydd och personlig skyddsutrustning
5583 Visningar •Demonstration av kardborreband för montering / installation av gasdetektor i fallskyddssele
5251 Visningar •VISOR Installationssteg
5504 Visningar •Desinfektionsprodukter med effekt på Corona Virus 2019 Ncov
4670 Visningar •Hörselskydd 3M
4068 Visningar •Statistik för arbete under 2014
4828 Visningar •LOTO_GuideBook_Europe_English
4917 Visningar •Remote Area Lighting System
3519 Visningar •Isol8 - The Ultimate absorberande för spill
3582 Visningar •Work Magazine - November 2012
4008 Visningar •KEE_DOME_MINI
3955 Visningar •TDS Speedglas 9100
4141 Visningar •Pocket Book of Lean Visuals
4262 Visningar •Instruktionsfilmer Sign hållare
3417 Visningar •PREMARK installationsmanual
4505 Visningar •D-S CSR Handbook
20830 Visningar •Hitta handske storlek - Storleksguide för handskar
13782 Visningar •Quick guide 3M PELTOR WS ProTac XPI_advanced (1)
11839 Visningar •3M jupiter manuell
9312 Visningar •83735-00000A Safety Data Sheet
8767 Visningar •D S 70:e oss broschyr
8688 Visningar •9100 Manuell
8056 Visningar •Förklaring av den nya EN ISO 374 standard kemikalier
7237 Visningar •LA600 UI A3 26 LANGUAGES 22 08 2019 598
7042 Visningar •Fallskydd flyer
7030 Visningar •EN 388 nya etiketter förklaring
6982 Visningar •3M TR 300 PAPR utbildning video
6566 Visningar •Hur man kalibrerar en 3M Jupiter luftflödesenhet
6549 Visningar •TR-300 Bruksanvisning
6098 Visningar •GuardianChemicalReport
5961 Visningar •3M Filterguide_DK
5827 Visningar •Urvalsguide respirator
5628 Visningar •Köpguide annonsen Health and Safety International - Europas tidskrift för anställda skydd och personlig skyddsutrustning
5583 Visningar •VARMEX 2000 Fördelar
5566 Visningar •VISOR Installationssteg
5504 Visningar •Chemical Recommendation Guides AlphaTec_58-128
Kommentering är inte påslagen på denna kursen.
1. Permeation breakthrough times and degradation data according to EN ISO 374:2016 AlphaTec® 58-128 Chemical agent CAS Number Breakthrough Time (min) Protection Index Degradation (%) Part Ammonium Hydroxide, 25% 1336-21-6 16.6 Cuff Ammonium Hydroxide, 25% 1336-21-6 62 3 14.5 Palm Formaldehyde, 37% 50-00-0 14.6 Cuff Formaldehyde, 37% 50-00-0 > 480 6 9.4 Palm Heptane 142-82-5 4.8 Cuff Heptane 142-82-5 > 480 6 -7.2 Palm Hydrogen Peroxide, 30% 7722-84-1 8.5 Cuff Hydrogen Peroxide, 30% 7722-84-1 > 480 6 28.5 Palm Sodium Hydroxide, 40% 1310-73-2 -2 Cuff Sodium Hydroxide, 40% 1310-73-2 > 480 6 -13.9 Palm Sulfuric Acid, 96% 7664-93-9 100 Cuff Sulfuric Acid, 96% 7664-93-9 44 2 80.8 Palm Permeation breakthrough times according to EN ISO 374:2016 0 1 2 3 4 5 6 < 10 10-30 30-60 60-120 120-240 240-480 > 480 Not recommended Splash protection Medium protection High protection Data given in the table above are based on results of laboratory tests performed on the palm or cuff area of the glove. These tests were run using standard test methods that may not adequately replicate any specific conditions of end use. We wish to highlight that permeation times do not equate to safe wear time. Safe wear time may vary depending on whether the PPE is donned correctly, the surrounding temperature, the chemicals’ toxicity, and other factors. Permeation information offered here is limited to the main protective material. Permeation times may vary around seams, zips, visors or any other joins or components of the PPE. It is the responsibility of your organization’s Health and Safety professional to undertake a risk assessment before choosing the appropriate PPE for the task at hand. Because Ansell has no detailed knowledge or control over the conditions of end use, any of these data must be advisory only, and Ansell must decline any liability. Ansell Healthcare Europe N.V. Riverside Business Park, Block J Boulevard International 55, 1070 Brussels, Belgium Tel. +32 (0) 2 528 74 00 Fax +32 (0) 2 528 74 01 http://www.ansell.eu E-mail info.europe@ansell.com
Dela detta innehåll
Dela länk
Dela på sociala medier
Dela via e-post
Snälla logga in att dela detta Dokument via e-post.