Documentation
Slutförd
Ose_directory e-shot
4118 Visningar •Kontrollera linje II underhållsmanual
5125 Visningar •Chemsplash Pro WD40 Test
4580 Visningar •ergonomi 2006
5110 Visningar •Ose_directory Suspension sele
4399 Visningar •Köpguide annonsen Health and Safety International - Europas tidskrift för anställda skydd och personlig skyddsutrustning
5561 Visningar •Demonstration av kardborreband för montering / installation av gasdetektor i fallskyddssele
5230 Visningar •VISOR Installationssteg
5476 Visningar •Desinfektionsprodukter med effekt på Corona Virus 2019 Ncov
4654 Visningar •Hörselskydd 3M
4055 Visningar •Statistik för arbete under 2014
4805 Visningar •LOTO_GuideBook_Europe_English
4894 Visningar •Remote Area Lighting System
3503 Visningar •Isol8 - The Ultimate absorberande för spill
3568 Visningar •Work Magazine - November 2012
3977 Visningar •KEE_DOME_MINI
3929 Visningar •TDS Speedglas 9100
4120 Visningar •Pocket Book of Lean Visuals
4234 Visningar •Instruktionsfilmer Sign hållare
3396 Visningar •PREMARK installationsmanual
4481 Visningar •D-S CSR Handbook
20806 Visningar •Hitta handske storlek - Storleksguide för handskar
13736 Visningar •Quick guide 3M PELTOR WS ProTac XPI_advanced (1)
11749 Visningar •3M jupiter manuell
9281 Visningar •83735-00000A Safety Data Sheet
8756 Visningar •D S 70:e oss broschyr
8654 Visningar •9100 Manuell
8034 Visningar •Förklaring av den nya EN ISO 374 standard kemikalier
7209 Visningar •LA600 UI A3 26 LANGUAGES 22 08 2019 598
7016 Visningar •Fallskydd flyer
7004 Visningar •EN 388 nya etiketter förklaring
6961 Visningar •3M TR 300 PAPR utbildning video
6533 Visningar •Hur man kalibrerar en 3M Jupiter luftflödesenhet
6521 Visningar •TR-300 Bruksanvisning
6062 Visningar •GuardianChemicalReport
5922 Visningar •3M Filterguide_DK
5803 Visningar •Urvalsguide respirator
5594 Visningar •Köpguide annonsen Health and Safety International - Europas tidskrift för anställda skydd och personlig skyddsutrustning
5561 Visningar •VARMEX 2000 Fördelar
5544 Visningar •VISOR Installationssteg
5476 Visningar •Chemical Recommendation Guide AlphaTec SolVex 37-695
Kommentering är inte påslagen på denna kursen.
1. Permeation breakthrough times and degradation data according to EN ISO 374:2016 AlphaTec® Solvex® 37-695 Chemical agent CAS Number Breakthrough Time (min) Protection Index Degradation (%) Part Formaldehyde, 37% 50-00-0 2.1 Cuff Formaldehyde, 37% 50-00-0 > 480 6 -10.3 Palm Heptane 142-82-5 8 Cuff Heptane 142-82-5 > 480 6 5.2 Palm Hydrogen Peroxide, 30% 7722-84-1 4.2 Cuff Hydrogen Peroxide, 30% 7722-84-1 > 480 6 3 Palm Methanol 67-56-1 72.8 Cuff Methanol 67-56-1 61 3 74.2 Palm Sodium Hydroxide, 40% 1310-73-2 -6.3 Cuff Sodium Hydroxide, 40% 1310-73-2 > 480 6 -22.4 Palm Sulfuric Acid, 96% 7664-93-9 64.2 Cuff Sulfuric Acid, 96% 7664-93-9 102 3 60.6 Palm Permeation breakthrough times according to EN ISO 374:2016 0 1 2 3 4 5 6 < 10 10-30 30-60 60-120 120-240 240-480 > 480 Not recommended Splash protection Medium protection High protection Data given in the table above are based on results of laboratory tests performed on the palm or cuff area of the glove. These tests were run using standard test methods that may not adequately replicate any specific conditions of end use. We wish to highlight that permeation times do not equate to safe wear time. Safe wear time may vary depending on whether the PPE is donned correctly, the surrounding temperature, the chemicals’ toxicity, and other factors. Permeation information offered here is limited to the main protective material. Permeation times may vary around seams, zips, visors or any other joins or components of the PPE. It is the responsibility of your organization’s Health and Safety professional to undertake a risk assessment before choosing the appropriate PPE for the task at hand. Because Ansell has no detailed knowledge or control over the conditions of end use, any of these data must be advisory only, and Ansell must decline any liability. Ansell Healthcare Europe N.V. Riverside Business Park, Block J Boulevard International 55, 1070 Brussels, Belgium Tel. +32 (0) 2 528 74 00 Fax +32 (0) 2 528 74 01 http://www.ansell.eu E-mail info.europe@ansell.com
Dela detta innehåll
Dela länk
Dela på sociala medier
Dela via e-post
Snälla logga in att dela detta Dokument via e-post.